Showing results: 226 - 240 of 427 items found.
-
19036 -
Chroma Systems Solutions, Inc.
The industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma’s 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards such as UL 1004-1.
-
Kharkovenergopribor Ltd.
Operational safety and reliability of electrical equipment and cables directly depend on the dielectric strength of the insulation. Portable and mobile high-voltage testers from KharkovenErgoPribor Ltd. are used for acceptance and operational testing of substation equipment and cable lines, as well as for checking the reliability of personal electrical safety equipment. Our testers range is represented by test systems that allow conducting high-voltage tests with DC and AC voltage, testing polymer insulated cables with very low frequency, testing and locating faults in cable sheath, as well as performing the initial burning of insulation on damaged sections of cable lines.
-
TESTEX Testing Equipment Systems Ltd.
The internal test room is made by high quality SUS304 stainless steel; heat insulating material: high density fiberglass wool; insulation material thickness: 80mm.The heat inside the internal room may not be conducted.
-
WTX Series Type II -
ECG KOKUSAI Co., Ltd.
Even 6 lead coil which is not conventionally made by changing the test cable into 6 from 4 is possible. The examination item of DC resistance, impulse, AC hi-pot and insulation resistance can be switched automatically at once.
-
TD Series -
b2 High Voltage
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
Shanghai Himalayal Co.
Diagnostic test that indicates the degree of cable insulation degradation. Rather than using only a VLF instrument to perform a go/no-go proof test, the Tan Delta, used in conjunction with a VLF hipot, permits the user to grade the deterioration level of many cables in order to prioritize replacement, rejuvenation, or to determine what additional tests may be useful.
-
1132 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.
-
ETL-10M -
Kharkovenergopribor Ltd.
ETL-10M is a cable test van with three-phase connection designed for testing cable insulation with DC (rectified) voltage up to 60 kV and testing other electrical objects with up to 50 kV AC voltage of industrial frequency.
-
AEMC Instruments
Full line of megohmmeters with test voltages 50V to 5000V. Capability to measure insulation resistance up to 10T. These rugged, weather resistant meters are accurate, reliable and built to perform. Battery, AC Powered & Hand-cranked models available.
-
GTPD-1 -
Kingrun Instrument Co., Ltd.
The GTPD-1 digital partial discharge tester is a mufti-function comprehensive intelligent diagnostic live inspection instrument. It can diagnose and test transformers, switches, GIS and cables on-line. It is a special instrument for testing and analyzing the insulation performance of power equipment.
-
1800 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.
-
1801 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.
-
Shenzhen Autostrong Instrument Co., Ltd.
This Proof Tracking Test Device is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator and mainly used test the resistance Tracking Performance of solid electrical insulation materials when they are exposing in electric affect impurity water situation.Mainly used for determination PTI and CTI items.
-
19056/19057 -
Chroma Systems Solutions, Inc.
Chroma’s Guardian 19056/19057 Hipot Analyzer is specially designed for testing and analyzing ultra-high withstand voltage. The series of models include 10kVac / 12kVdc / 20kVdc with maximum AC20mA / DC10mA output that can perform AC / DC withstand voltage and insulation resistance tests with contact check during production line test.
-
1180 IN -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages(DC) : 250V, 500V, 1000V● Continuity test : 50 Ω● AC voltage measurement : 500V● Color-coded scale.● Fuse protected.